The Canon TX-20P Full Auto Non-Contact Tonometer & Pachymeter is an advanced 2-in-1 ophthalmic diagnostic system that combines non-contact intraocular pressure (IOP) measurement with integrated central corneal thickness (CCT) pachymetry.
Key Feature — Built-in Pachymetry & Compensated IOP:
Unlike the standard TX-20 model, the TX-20P features a built-in non-contact pachymeter that measures central corneal thickness simultaneously with IOP in a single touch. Because corneal thickness significantly affects IOP readings, the system automatically calculates Compensated IOP (C.IOP)—making it an essential tool for accurate glaucoma screening, diagnosis, and pre-/post-refractive surgery management. Its 3D full-auto alignment and soft air puff ensure rapid, comfortable bilateral examinations from alignment to printout.
The Canon RK-F2 Full Auto Ref-Keratometer is an automated ophthalmic diagnostic instrument designed to measure objective refractive error (sphere, cylinder, axis) and corneal curvature (keratometry). Featuring Canon's 3D Full-Auto Alignment and Measurement technology, the operator simply presses the start button once to automatically align, focus, measure both eyes, and print the results. Its compact footprint, tiltable color LCD screen, and ability to measure pupils as small as 2.0 mm make it ideal for busy ophthalmology clinics and optical practices.
New Arrival
NIDEK
ARK-1a
The ARK-1a is a multimodality device that includes autorefraction and keratometry. This automated instrument measures with objective accuracy and features accommodation testing and retro-illumination. Super Luminescent Diode (SLD) technology allows for accurate measurements on patients with cataracts, corneal opacities, IOLs, and post LASIK procedures. The ARK-1a also utilizes a multiple pupil zone imaging method combined with rotary prism technology and an auto alignment Eye Tracking System to ensure consistent, accurate, reliable and repeatable data.
The Topcon DRI OCT Triton plus is a high-end multimodal Swept-Source Optical Coherence Tomography (SS-OCT) system integrated with a non-mydriatic fundus camera. Utilizing a 1,050 nm invisible scanning laser at 100,000 A-scans per second, it penetrates deep into the choroid and sclera—even through media opacities like cataracts—while minimizing patient eye movement. As the flagship "plus" model, it supports true-color fundus photography, Fluorescein Angiography (FA), Fundus Autofluorescence (FAF), and OCT Angiography (OCTA) alongside 12 mm × 9 mm widefield 3D scans.
The Alcon VERION™ Reference Unit is a preoperative ophthalmic diagnostic and surgical planning workstation designed to improve precision in cataract surgery.
It non-invasively captures high-resolution digital images of the patient's eye—mapping scleral blood vessels, limbus, and iris features as a unique "fingerprint of the eye"—to calculate intraocular lens (IOL) power, determine astigmatism alignment, and plan incision locations.
Key Advantage Over Newer Successor Systems:
Unlike later-generation setups such as the VERION™ Navigation System, which rely on integration with the ARGOS® Biometer for preoperative measurements, the VERION™ Reference Unit operates completely standalone. It does not require pairing with ARGOS® or additional biometric hardware to capture reference images and generate complete surgical plans, making it a cost-effective, space-saving, and flexible solution for any clinic.
New Arrival
KOWA
SL-17
The Kowa SL-17 Portable Slit Lamp is a lightweight, cordless handheld biomicroscope designed for stereoscopic examination of the anterior segment of the eye (cornea, iris, lens, and conjunctiva). Weighing under 800 g, it provides the optical performance of a stationary slit lamp with full mobility, making it ideal for bedside examinations, home visits, pediatrics, emergency rooms, and veterinary ophthalmology. This particular unit is equipped with a mounted digital camera system (RICOH PENTAX Q-S1), enabling clinicians to capture and document high-resolution images and videos of anterior segment findings.
This ophthalmic laser workstation pairs the compact NIDEK GYC-1000 532nm Green Laser Photocoagulator with Carl Zeiss Slit Lamps renowned for their superior optical clarity. Combining NIDEK's reliable, high-power solid-state green laser technology with ZEISS's precision stereomicroscopy, this system provides an efficient, space-saving solution for retinal photocoagulation and anterior segment examinations.
• Compact Yet Powerful 532nm Green Laser (NIDEK GYC-1000):
Utilizing a diode-pumped solid-state (DPSS) laser source, the GYC-1000 delivers up to 1,700 mW (1.7 W) of continuous-wave green laser energy in an ultra-compact tabletop footprint. It provides predictable, consistent burns even through mild media opacities
• Legendary Carl Zeiss Optics:
Integrated with a Carl Zeiss Slit Lamp (SL 120 / SL 130 series) via a dedicated laser delivery adapter, offering crisp, high-contrast visualization of the fundus and precise micromanipulator targeting.
The TOMEY AL-4000 is a high-precision ultrasound A-scan biometer and pachymeter designed for reliable preoperative cataract evaluation. Configured here with the dedicated Chinrest System and the TOMEY AL-4050 IOL Calculation Unit, this complete workstation streamlines accurate axial length measurement—even through dense cataracts—and comprehensive intraocular lens (IOL) power calculations.
The ZEISS VISULAS Trion is a high-performance multi-wavelength ophthalmic laser photocoagulation system featuring green, yellow, and red wavelengths in a single compact unit. Combining versatile wavelength selection with ZEISS's renowned precision optics, it delivers safe, reproducible, and effective laser therapy for a wide range of retinal and glaucoma conditions.
The ZEISS Cirrus HD-OCT 4000 (Cirrus HD-OCT or Cirrus) enable examination of the posterior and anterior of the eye at an extremely fine spatial scale, without surgical biopsy or even any contact with the eye. The Cirrus HD-OCT builds on and refines the retinal imaging technology first introduced with the ZEISS Stratus OCT HD-OCT stands for "high-definition optical coherence tomography."